The [sub]system consists of two identical resonant optical scanners (type SC), scanner "A" and scanner "B", in a MASTER/SLAVE mode, to provide ultra stable scanning beam motions. The system can be used as a "stand alone" unit, in the laboratory or as a portable instrument, or incorporated into a larger instrument/system. The two identical scanners are ONE FIXED FREQUENCY each, picked from the range of 5 Hz to 20 kHz. They are small size, light weight, low cost and long life devices. They require low power drive electronics and do not radiate any electromagnetic interference (EMI). The scanners have high amplitude stability and very low amplitude jitters; wobble is less than 1 arc sec. The scanners are IR, VIS, UV and high vacuum capable. Reference signal and position output available.
The PLD-2S driver phase locks two identical scanners. Scanner "B" is phase locked to scanner "A" (the slave is locked to the master). The phase relationship to the master is factory set to customer requirement (0° to 360°) and is front panel adjustable in a range of ±45° min. The driver can be a fully integrated driver with front panels controls and internal power supplies or a printed circuit board level driver. The dimensions of the cased driver are: 12" × 10" × 3.8". The PLD-2S-PC driver is a printed circuit board level driver, which requires an external ±15V DC power supply.
FRONT PANEL CONTROLS |
|
POWER |
Power switch to turn the drive "ON" |
OUTPUT A |
To interconnect scanner "A" (master) to the driver |
POSITION MONITOR A |
Scanner "A" position output, BNC connector |
AMPLITUDE CONTROL A |
Scanner "A" amplitude control POT |
OUTPUT B |
To interconnect scanner "B" (slave) to the driver |
POSITION MONITOR B |
Scanner "B" position output, BNC connector |
AMPLITUDE CONTROL B |
Scanner "B" amplitude control POT |
PHASE |
To adjust the phase of the scanner "B" in relationship to scanner "A", ±45° minimum range of adjustment around |