FEATURES AND ADVANTAGES
|
|
|
|||
The LIA-410 single phase lock-in amplifier is a general purpose benchtop instrument. The INPUT SIGNAL CHANNEL amplifies the input signal to a level suitable for the demodulator. The input circuit can accept a differential or single-ended input, via the front panel signal BNC. Jumper options within the unit allow a high impedance differential input, a low impedance (100 ohm) differential input, or to be connected to ground for single-ended operation, via the front panel BNC. The input channel can be either AC or DC coupled via internal jumper selection. It is recommended that the unit is used in DC coupled mode for improved noise performance. In this mode, up to +/-10V of DC offset is allowed before saturation for gain setting from 1V to 300uV. A +/-1V of DC offset is allowed for gain setting from 100uV to 10uV; and +/-300mV of DC offset is allowed for the gain setting of 3uV.
Frequency | 10Hz to 100kHz |
Sensitivity | 3uV to 1V (for 1V output) switched in 1, 3, 10 steps |
Input impedance | 1012 ohm || 1nF, dc coupled |
Maximum inputs | +/-16V before input protection circuitry is activated |
Gain accuracy | 1% |
Gain stability | 200ppm/°C |
Dynamic reserve | 60dB |
A very high bandwidth DEMODULATOR processes the signal and removes offsets, and a first order LOW PASS FILTER amplifies the signal before output via a front panel BNC.
Time constant: 100uS to 30s in 1, 3 & 10 steps
Output | +/-1V output corresponds to full-scale input. Short circuit protection included. |
Offset | Up to 1x full scale, switch between "ON" and "OFF". |
The REFERENCE INPUT CIRCUITRY uses a phase locked loop to lock on to a range of signals, such as TTL pulses or sinusoidal waveforms. A phase shifting circuit allows the removal of the reference signal with relation to the signal input, which can be monitored at both the reference frequency and twice the reference frequency.
Frequency | 10Hz to 100kHz |
Input impedance | 5.6M ohm ac coupled |
Trigger | Sine: 100mV rms min (15V max.) |
Pulse: 5V, 95% mark/space ratio min. | |
Acquisition time | 10s max. |
Phase control | 90° steps + fine shift in range 0°-100° |
Phase drift | 0.1°/°C |
GENERAL | |
Power | 115V ac, 230V ac; 50-60Hz; 10VA max. |
Dimensions | 17.5" (W) × 3.5" (H) × 7.5" (D) |
440mm (W) × 87mm (H) × 190mm (D) | |
19" rack mount available as a special order | |
Temperature range | 0-50°C (operational) |
Warranty | 2 years from date of shipment |
STANDARDS | |
Electrostatics discharge | BS EN 61000-4-2 Level 2 |
Surge | BS EN 61000-4-5 Level 3 |
Burst & Transient | 61000-4-4 Level 2 |
RF Emissions | BS EN 50081-2 |
RF Immunity | BS EN 61000-4-3/ BS EN 50082-2 |
Low Voltage Directive | BS EN 61010-1 |